Portable Biphasic Defibrillator Medical First Aid Equipment
Item No.: YS-8000A-1
Automated External Defibrillator, As Known As AED, Portable Life Saving Device That Can Give A Casualty's Heart An Electric Shock When It Has Stopped Beating.
Medical First Aid Equipment Portable Biphasic Defibrillator Dimension(L*W*H): 320x205x410
Weight: 9.5kg
Technical Specification
Defibrillator Type: Manual, Synchronized, Asynchronized
Output Waveform: Biphasic Technology
Energy Accuracy: <±1%
Energy Selection: 0, 3, 5, 7, 10, 20, 30, 50, 100, 200, 300, 360 Joule(Nominal Ata Resistance of 50)
Charging Time: Maximum 8 Seconds to 360 Joules
Standard Adult/Pediatric Paddles: Reusable External Adult Paddles(Pediatric Paddles Integrated)
Power Requirement
AC Power Supply; 110v, 60Hz/220V, 50Hz
Vehicle Voltage: DC 12V
Internal Battery Backup
Battery Type: Rechargeable Lead-Acid Battery
Charging Time: Time-Minimum of 4 Hours for Full Charging
Battery Charging: During AC Power Supply Operation of the Device
Charging/Low Battery Indication: Red LED
Battery Capacity: 100% of the Battery Will Provide 120 Mins of Monitoring, and 30 Discharges at 30 Joules
Display
LED Dimensions: 7' Diagonal(155mmx88mm) Which is Easily Read from A Distance
Type: High-Resolution True-color Graphic LED
Resolution: 480*234
- Provide cardioversion facilities with waveform annotated on the screen
- Display 4 seconds of ECG at 2mm/sec, ECG selectable from leads Ⅰ, Ⅱ, Ⅲ, when used with a 3-lead cable, and Ⅰ, Ⅱ, Ⅲ a VL, aVR, aVF and V when used with a 5-lead cable.
- Display prompts, waveform settings, battery status, event summary and fault codes. Energy selected is displayed by the push button under the screen.
ECG
ECG Lead: Ⅰ, Ⅱ, Ⅲ, AVR, AVL, AVF, V1-V6, GND
S-T Segment Analysis: -2.0~2.0mv
Arrhythmia Analysis: Yes
Protection: With Stand 4000vAc/50Hz Voltage in Isolation and Work Against Electrosurgical Knife and Defibrillation
Standard Parameter & Configuration
ECG/RESP/Defibrillator
- Provide audible and visual alarms for heart rate violation, VF and VT.
- Provide a strip printer that annotates waveform, events, time code.
- Have a 5-lead patient cable as an option to a 3-lead cable.
- Supplied with external re-usable paddles and packs of paper rolls for the printer.
Get Price
Write down your demand below and we will contact you within 24h!