Categories

dual syringe pump microfluidics

Item No.: YSZS-620
Features :
1.Double CPU- Safter infusion
2. Numberic Keypad- More Convenient
3. Occlusion, Alarm, brightness level adjustable
4. Optional injection modes
5. Color LCD, user friendly
6. 3000mAh Li-ion Battery, backup time at least 10hr
  • BrandYsenmedical
  • Model numberYSZS-620
  • Warranty1 year
  • Customizedyes
  • Lead time7 days
  • Packagecarton
  • Description
    YSZS-620 dual syringe pump microfluidics
    1.Double CPU- Safter infusion 
    2. Numberic Keypad- More Convenient 
    3. Occlusion, Alarm, brightness level adjustable
    4. Optional injection modes
    5. Color LCD, user friendly
    6. 3000mAh Li-ion Battery, backup time at least 10hr

     
    Specifications:
    Infusion Mode Micro and continuous injection
    Syringes 5mL,10mL, 20mL, 30mL, 50/60mL syringes
     and self-defined for customer's brand.
     Rate Unit
    (including drug weight unit)
    mL/h, mg/h, µg/h,
    µg/kg/min, mg/kg/min, µg/kg/h, mg/kg/h.
    Flow Rate Range 5ml syringe: 0.01-60mL/h
    10mL syringe: 0.01 ~ 300 mL/h
    20mL syringe: 0.01 ~ 400 mL/h
    30mL syringe: 0.01 ~ 600 mL/h
    50mL syringe: 0.01 ~ 1200 mL/h
    Increment 0.01 mL/h steps (for settings from 0.01 to 99.99 mL/h);     1 mL/h steps (for settings from 100 to 999 mL/h)
    Volume Limit 0.1~ 9999.9 mL and empty mode available
    Flow Rate Deviation ≤ ± 2% 
    Purge Rate 5ml syringe:  60mL/h
    10mL syringe: 300 mL/h
    20mL syringe: 400 mL/h
    30mL syringe: 600 mL/h
    50mL syringe: 1200 mL/h
    KVO Rate  0.01  ~ 5 mL/h (adjustable)
    Bolus Mode Bolus rate adjustable, Automatic
    Occlusion Pressure Pressure detection device with
    10 sensitivities setting, 10 ~ 140KPa.
    Parameter Changing During Syringe Yes, VTBI and Rate can be changed
    History (Event Log) 10000 events can be stored and exported 
    Drug Library Hundreds drugs can be imported and exported.
    Alarming and Button Sound Setting  10 levels setting
    Display 3.5" TFT color LCDdisplay
    Keypad Mode Numerical button
    Keypad Lock  Yes, optional
    Power Source AC: 100V ~ 240V, 50Hz/60Hz, ≤ 25VA
    Battery Rechargeable Lithium battery: DC11.1V, 3000mAh, workinghours≥7 hours at 5mL/h, remaining battery displayed.
    Classification Class Ⅱ, CF, IPX4
    Dimensions and N.W. 340mm x 200mm x 158mm; 2.1kg
     
    * Bright color and large LCD Touch Screen
    *Small Size, Easy to carry and economical to transport  
    *Three infusion tbes any standard 
    *KVO & Bolus Function 
    *Heating fuction &Double CPU 
    * Real time display 
     
    * Bright color and large LCD Touch Screen
    *Small Size, Easy to carry and economical to transport  
    *Three infusion tbes any standard 
    *KVO & Bolus Function 
    *Heating fuction &Double CPU 
    * Real time display 


    Technical Specification:

    Infusion rate range
    Adjustable drop rate range: 1 /min~400 drops/min 
                              (step: 1 drop /min)
    Adjustable flow rate range: 1ml/h~1200ml/h
                             (step 0.1ml/h)
    Purge rate: 800ml/h
    KVO rate: 1ml/h (less than 100ml/h)
              2ml/h (100~300ml/h)
              3ml/h (greater than 300ml/h)
    Infusion volume range: 1ml~9999.9ml (step: 0.1 ml)
    Maximum accumulated volume: 9999.9ml (step: 0.1 ml)
    Infusion Time range: 1min~9999min (step: 1 min)

    Infusion accuracy: Within ±3% (using calibrated high quality IV set)
                       Mechanical precision: within ±2%

    Occlusion alarm threshold:
             High: 800 mmHg ± 200 mmHg (106.7kPa±26.7kPa)
    Medium: 500 mmHg ± 100 mmHg (66.7kPa±13.3kPa)
    Low: 300 mmHg ± 100 mmHg (40.7kPa±13.3kPa)
    Alarm: Infusion Complete, Empty, Faulty Signal, Misoperation, Occlusion, Door Open, Air Bubble, Low Battery, Setting Error, AC power off, Idle.

    Size: 515mm(L)×145mm(W), allowed deviation: ±5%

    SpO2 sensor
    Type: Finger clip type
    Wire length: 3000mm, allowed deviation: ±5%
    Human body contact materials: Silicone

    Size: 188 mm(L)×198 mm(W)×228 mm(H)
    Net weight: 2.5kg

    Technical Specification:

    Infusion rate range
    Adjustable drop rate range: 1 /min~400 drops/min 
                              (step: 1 drop /min)
    Adjustable flow rate range: 1ml/h~1200ml/h
                             (step 0.1ml/h)
    Purge rate: 800ml/h
    KVO rate: 1ml/h (less than 100ml/h)
              2ml/h (100~300ml/h)
              3ml/h (greater than 300ml/h)
    Infusion volume range: 1ml~9999.9ml (step: 0.1 ml)
    Maximum accumulated volume: 9999.9ml (step: 0.1 ml)
    Infusion Time range: 1min~9999min (step: 1 min)

    Infusion accuracy: Within ±3% (using calibrated high quality IV set)
                       Mechanical precision: within ±2%

    Occlusion alarm threshold:
             High: 800 mmHg ± 200 mmHg (106.7kPa±26.7kPa)
    Medium: 500 mmHg ± 100 mmHg (66.7kPa±13.3kPa)
    Low: 300 mmHg ± 100 mmHg (40.7kPa±13.3kPa)
    Alarm: Infusion Complete, Empty, Faulty Signal, Misoperation, Occlusion, Door Open, Air Bubble, Low Battery, Setting Error, AC power off, Idle.

    Size: 515mm(L)×145mm(W), allowed deviation: ±5%

    SpO2 sensor
    Type: Finger clip type
    Wire length: 3000mm, allowed deviation: ±5%
    Human body contact materials: Silicone

    Size: 188 mm(L)×198 mm(W)×228 mm(H)
    Net weight: 2.5kg