Newborn babies are very afraid of the cold and have difficulty adapting to the external environment. The temperature in the incubator is very reasonable, and the temperature is controlled according to the baby's body temperature.
Function features 1. Microprocessor based servo controlled temperature system 2. Alarms functions: Power failure; Over temperature; Temperature deviation; Temperature sensor failure; Fan failure; 3. Humidity is adjustable continuously 4. A keypad lock prevent inadvertent changes the setting 5. Integral timer to record therapy time 6. Skin temperature sensor failure protect function avoid over temperature 7. Air temperature, skin temperature, timer and heat power separately displayed by LED 8. >37 °C temperature setting 9. Silence/reset button for alarms 10. Trough for pulling and pushing, which is convenient to add water and wash 11. Fan with low noise and long life-span 12. Temperature deviation and over temperature could be amended in front panel directly 13. A second thermal cut-off function for more safety 14. The infant bed inclination angle is adjustable 15. Six operating windows, two sides operating windows can be swiveled 16. Heater is electrically cut-out if air temperature inside incubator exceed 40 °C
Standard configuration Main body(including the transparent hood, control system, infant bed, water trough), skin temperature sensor, I. V. Pole, mattress, cabinet, castors
Optional parts: Phototherapy up side unit; Phototherapy from up and down sides; RS232(485)conncector; Tray/pole; Infant bed pulled from side door; Infant bed pulled from side and front door; Double wall hood
Technical data: 1. Wer supply: AC 110/220V 60/50Hz 2. Power input: ≤ 420VA 3.Operating conditions: Evironment temperature: 20~30°C Evironment relative humidity: 30%~75%RH Evironment air velocity of flow: <0.3m/s 4. Air Temperature control range: 25~38°C 5. Skin temperature control range: 32~38.5°C 6. Skin temperature sensor accuracy: +/-0.3°C 7. Temperature fluctuation: +/-0.5°C 8. Uniformity of mattress temperature: ≤ 0.8°C 9. Warm-up time: ≤ 45min 10. Internal noise level: ≤ 55dB 11. Infant bed tilt angle: +10degree 12. Mattress size: 65cm(L)X 37cm(W) 13. Trough capacity: 1200ml 14. Air filter: 0.5um
Package: Each unit is packed in two wooden crate Size (control unit and cabinet): 120X 70X 96CM N. W.: 80KG G. W.: 110KG Hood: 97X 56X 63CM N. W.: 15KG G. W.: 40KG
Transport and storage Environment Temp: -10--+70°C Environment Relative Humidity: ≤ 80% Atmospheric Pressure: 500~1060Hpa
Get Price
Write down your demand below and we will contact you within 24h!