YSPM-F15M Multi-parameter Modular Patient Monitor (15 inches)

Item No.: YSPM-F15M
  • BrandYSENMED
  • Model numberYSPM-F15M
  • WarrantyOne year
  • CustomizedYES
  • Lead time20 WORKINGD AYS
  • PackageWooden case
  • Description
    Technical Data Sheet - Release V2.2
     
    The  F15 patient monitor is designed to match the pace and unique needs of adult, pediatric, and neonatal intensive care; anesthesia and peri-operative care; OR and cardiac care environments.
    An optional USB Mouse/Keyboard control eases navigation and data entry.
    An optional HDMI output eases observation from a long distance.


    Features
    Core
    Newly advanced A9 main board with Linux OS, calculating speed is 4 times faster than traditional products
    Support storage of 2160 hours trend table and graph review, 2 hours waveform review, 2000 groups NIBP review and 2000 alarm events review
     
    Body
    15 inch high-brightness TFT LED
    Support display 9~13 waveforms
    Support 7 channel ECG waveform display simultaneously  
    Optional touch screen
    Optional HDMI output
     
    Printer
    Built-in high-speed 50mm thermal printer
     (Brand: SEIKO, Japan)
     
    Central System
    Optional Build-in wireless network module, supporting wired or wireless connection to the central monitoring station.
    Optional Support HL7 (Health Level Seven)
    Alarm
    Three-level acousto-optic alarm
    Sensor-off alarm
    Paper out alarm
    Support alarm review 
    Support alarm pause
     
    Linux OS
    Support operation with mouse and computer keyboard (option)
    Multi-display mode to meet different clinical requirement, including standard interface, big font, OxyCRG, trend graph, NIBP review and full leads ECG interface.
     
    NIBP self-test mode: including overpressure test, static pressure test and air leakage test.
    Generate ID automatically when register a new patient
    Support medical history search by patient ID, name and mobile number
    18 types of Arrhythmia analysis and real-time S-T segment analysis and pacemaker detection
    Drug calculation and titration table 
    Support multi-language display
    Support online software upgrading by net/USB
     
    Performance Specifications
    Dimension and Weight
    Dimension: 380mm*360mm*160mm
    Weight: 4.5kg(excluding accessories)
     
    Power Supply
    Voltage: AC100~240V, 50/60HZ, Power≤60W
    Display
    15" color TFT LED  
    Resolution: 1024*768 pixels
    Battery (Pluggable)
    Type: Rechargeable lithium battery 14.8V/2200mAh
    Charge Cycle: ≥500 times
    Working time: 2 hours (optional larger battery for 4-5 hours)
    Recorder (Option)
    Method: Thermal printer
    Paper width: 50 mm (1.97 in)
    Printing speed: 12.5/ 25/ 50 mm/s
    Trace: Max. 3 tracks
    Recording way: Real-time Recording, Review Printing,  
    Periodic Recording, Alarm Recording


    Alarm
    Level: Low, medium and high
    Indication: Auditory and visual
    Alarm volume adjustable
    Alarm pause time: 1min, 2min
    Parameter alarm type: Latch/ Unlatch
     
    Input Device
    Touch screen (option)
    Knob (Standard)
    Keypad input (Standard)
    Mouse/ Keyboard input (option)
     
    System Output & Extensible Interface
    Ethernet Network: 1 standard RJ45 socket
    USB Port: 1
    Video Output:  1 HDMI port (option)
     
    Operating Environment
    Temperature:  5 ~ 40 ℃
    Humidity:  15% ~ 80% (non-condensing)
    Atmosphere pressure:  86 KPa ~ 110 KPa
    Transportation and Storage Environment
    Temperature: -20~50 ℃
    Humidity: 10%~90%  (non-condensing)
    Atmosphere pressure:  86 KPa ~ 110 KPa
     
    Safety
    IEC60601-1 Approved, CE marking according to MDD93/42/EEC
    With reference to RoHS Directive 2011/65/EU recasting
    Trend & Reviewing
    Trend: 2160 hours
    ARR events: 128 groups of ARR events and associated waveform
    NIBP measurement reviewing: 2000 groups
    Waveform review: 2 hours


    Alarm event: 2000 groups of parameter alarms events and associated parameter


    ECG
    Lead mode: 3/5 Leads, I, II, III or I, II, III, AVR, AVL, AVF, V
    Protection: Breakdown Voltage 4000VAC 50/60Hz; Defibrillator proof
    Gain: 2.5mm/mV (×0.25), 5.0mm/mV (×0.5), 10mm/mV (×1), 20mm/mV (×2), 40 mm/ mV (×4), Auto
    Sweep speed: 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s
    ECG signal range:  ±12 mV (Gain × 0.25)
    Accuracy: ±1bpm/ ±1%, whichever is greater
    Resolution: 1 bpm
    Leakage Current < 10 μA
    Baseline Recovery:
    ≤ 3s after defibrillation (Monitor mode)
    ≤ 1s after defibrillation (Surgery mode)
    Bandwidth: Surgery 1 ~ 25 Hz
    Monitor 0.5 ~ 40 Hz
    Diagnostic 0.05 ~ 120 Hz
    Indication of Electrode Separation: Every electrode (exclusive of RL)
     
    Heart Rate
    Measure range:
    Adult: 0bpm; 10 ~ 300 bpm
    Neo/Ped: 0bpm; 10 ~ 350 bpm
    Resolution: 1 bpm
    Accuracy: ± 1% or ± 1bpm, whichever is greater
     
     
     
     
    ST Measurement
    Range: -2.0 ~ +2.0 mV
    Accuracy: -0.8mV~+0.8mV: ±0.02mV or ±10%, whichever is greater
    Other range: unspecified
    Resolution: 0.01mV
     
    Respiration
    Method: Impedance between RA-LL, RA-LA
    Gain: ×0.25, ×0.50, ×1, ×2, ×4
    Respiration Rate: 0bpm, 6 ~ 150 BrPM
    Sweep speed:  6.25 mm/s, 12.5 mm/s, 25mm/s
    Resolution: 1 BrPM
    Accuracy: ±2 bpm or ±2%, whichever is greater
    Apnea Alarm: 10 ~ 60 s
     
    NIBP
    Method: Oscillometric
    Measure mode: Manual, Auto, STAT
    Measure Interval in AUTO Mode 1~480 min
    STAT mode cycle time: Keep 5 minutes, at 5 seconds interval
    Measure and Alarm Range: 
    Adult: SYS:  30 ~ 270 mmHg
               DIA:  10 ~ 220 mmHg     
               MEAN:  20 ~ 235 mmHg
    Pediatric: SYS:  40 ~ 235 mmHg
    DIA:  10 ~ 220 mmHg     
    MEAN:  20 ~ 225 mmHg
    Neonate:   SYS:  30 ~ 135 mmHg
    DIA:  10 ~ 110 mmHg     
    MEAN:  20 ~ 125 mmHg
    Static pressure accuracy: ±3mmHg
    Resolution: 1mmHg
    Accuracy: Maximum Mean error ±5mmHg           
             Maximum Standard deviation ≤8mmHg
    Over pressure Protection: Dual protection via software & hardware
     
    Temperature
    Technique: Thermistor probe (2.25K)
    Channel:  Dual-channel, provide T1; T2; ΔT
    Measuring and Alarm Range:
    0.0 ℃~ 50 ℃ (32℉~ 122℉)
    Unit: Celsius (℃), Fahrenheit ( ℉)
    Resolution: 0.1℃or 1℉
    Accuracy: ±0.1℃(exclusive probe)
     
    SpO2 (Digital Technic)
    Measurement Range: 0 ~ 100 %
    Resolution: 1 %
    Response Modes: Low, Medium, High
    Accuracy:  ±2% (70% ~ 100%)
                ±3 % (35% ~ 69%)
    Unspecified (0 ~ 34%)
    Support Pitch tone and multi-level volume   
     
    Pulse Rate
    Measuring and Alarm Range: 25~250bpm
    Accuracy: ±1% or ±1 bpm, whichever is greater
    Resolution: 1bpm
     
    Nellcor-SpO2 (Option)
    Measurement Range: 0 ~ 100 %
    Resolution: 1 %
    Accuracy:   70% ~ 100%, ±2 % (adult)
                 70% ~ 100%, ±3 % (Neonate)
                 70% ~ 100%, ±2 % (Low Perfusion)
                 0% ~ 69%, unspecified
     
    Pulse Rate
    Measurement range: 20 ~ 300 bpm
    Resolution: 1bpm
    Accuracy:
    ±3 bpm (20 ~ 250 bpm)
    unspecified (251~300 bpm)
     
    Masimo SpO2 (Option)
    - Measurement Range: 0 ~ 100 %
    - Resolution: 1 %
    Accuracy:  
    70% ~ 100%, ±2 % (adult/ pediatric, non-motion conditions)
    70% ~ 100%, ±3 % (neonate, non-motion conditions)
    70% ~ 100%, ±3 % (motion conditions)
    0% ~ 69% unspecified
    Pulse Rate
    Measurement range: 25 ~ 240 bpm
    Resolution: 1bpm
    Accuracy: ±3 bpm (non-motion condition)
     
    EtCO2 (Mainstream/ Sidestream) (Option)
    Measure method:  Non-dispersive infrared (NDIR)
    Measure Range:  0 ~19.7% (0 ~ 150 mmHg)
                     0 ~ 20 kPa
    Resolution: 0.1 mmHg
    CO2 Accuracy:  
    0 ~ 40 mmHg, ±2 mmHg
    41 ~ 70 mmHg, ±5% of reading
    71 ~ 100 mmHg, ±8% of reading
    101~ 150 mmHg, ±10% of reading
    at 760 mmHg, ambient temperature of 25℃)
    Respiratory Rate:  Range: 3 ~150 BrPM
                    Accuracy: ±1 bpm
     
    EtCO2 (Micro-stream) (Option)
    Measure method:  Non-dispersive infrared (NDIR)
    Measure Range:  0 ~19.7% (0 ~150 mmHg)
                     0 ~ 20 kPa
    Sample Rate: 50 mL/min ±10mL/min
    Resolution:  0.1 mmHg (0 ~ 50 mmHg)
               0.25 mmHg (50 ~ 114 mmHg)
    CO2 Accuracy:  0 ~ 40 mmHg, ±2 mmHg
                    41 ~ 70 mmHg, ±5% of reading
                    71 ~ 100 mmHg, ±8% of reading
                   101~ 150 mmHg, ±10% of reading
            at 760 mmHg, ambient temperature of 35℃)
    Respiratory Rate: Range: 3 ~120 BrPM
                  Accuracy: ±1 bpm
     
    Depth of Anesthesia (CSI) (Option)
    EEG sensitivity:  ± 400μV


    Noise: < 2μVp-p, < 0.4μV RMS, 1-250 Hz

     