Feature
Dual plug-ins: EtCO2, 2lBP, 4lBP, CO, AG can be optional; modular monitor is more convenient for detection and more economical;
Data: Trend data storage for up to 360 hours; printing for data, waveform, and trend diagrams;
User Interface: 15"color TFT LCD screen, available in 15 languages;
Versatility: Suitable for adults, pediatrics, and neonates; widely applicable in physician's offices, OR/OT,ICU,CCU, NiCU, clinics, etc;
Communication:WAN communication function to network with Central Monitoring System,supporting both wired and wireless networking and compatibility with HL7 systems;
Accuracy Assurance:"Auto-current drift balanced system" ensure accuracy,along with unique patents for impedance RESP and ECG waveform stability during electrosurgical procedures;
Advanced Functions: includes ST-segment analysis, bed-to-bed view, venipuncture support, pacemaker monitoring,arrhythmia analysis and 5 calculations(Hemodynamic, Drug Dose, 0xygenation, Renal Founction, Ventilation);
Specialized Tests: Offers unique nasal tube respiration testing suitable for patients with burns, upper airway obstructions, and newborns.
Specifications
ECG
Input: 3/5/10 wires ECG cable
Lead section: I, ll, lll, aVR,aVL, aVF, V1-V6
Gain selection: x1/4,x1/2,x1,x2,x4 and automatic
Sweep speed: 3.125,6.25,12.5,25,50mm/s
Heart rate range: 15~350bpm
Calibration: ±1mv
Accuracy: ±1bpm or +1% (select the bigger data)
SPO2
Display type: Waveform, Data
Measurement range: 0~100%
Accuracy: ±3%(between 70%~100%)
SpO2 resolution: 1%
Pulse rate range: 25~250bpm
Accuracy: ±1bpm or ±2%(select the bigger data)
PR Resolution: 1bpm
PI
Measurement range: 0.00~20.0%
Accuracy: Not defined
Resolution: 0.00~9.99%:0.01%
10.0~20.0%:0.1%
Respiration
Measurement range: 0~120rpm
Accuracy: ±1rpm or ±5% (select the bigger data)
Resolution: 1rpm
ETC02-Plug & Play(0ption)
Measurement type: Main/Side stream
Measurement range: 0%~19.7%,0~150mmHg,0~20kpa
Accuracy: 0~40mmHg ±2mmHg
41~70mmHg ±5% of reading
71~100mmHg ±8% of reading
101~150mmHg ±10% of reading
2-Temperature(Rectal & Surface)
Number of channel: 2 channel
Measurement range: 0°C ~50°C
Accuracy: ±0.2°C
Resolution: 0.1°C
Display: T1, T2, ∆T
Unit: °C/°F selection
2-IBP/4-IBP(0ption)
Measurement range: -10~300mmHg
Number of channel: 2 or 4 channel
Accuracy: ±1mmHg or ±2%(select the bigger data)
lBP Pressure Tag: ART, CVP, RVP, LAP, RAP, PAP, LCP, LVP,
AO, FAR, BAP, VAP, LV, PA, P1, P2,P3, P4
NIBP
Philosophy: Oscillometric method
Measurement parameter: Systolic, Diastolic, Mean
Measurement method: Manual, Auto, Continuous
Measuring range: SYS:30-270mmHg
DIA:10-200mmHg
MAP:20-220mmHg
Resolution: 1mmHg
Accuracy: Max average error:±5mmHg
Max standard deviation:8mmHg
Cardiac output(Option)
Measuring Method: Thermodilution
Measurement range: C.O.:0.1~20.0L/min
TB:20.0'C~45.0°C
Tl: 0.0'C~30.0°C
Accuracy: C.O.:±5% or ±0.1L/min
(select the bigger data)
TB:±0.2°C Tl:±0.2°C
Resolution: CO:0.1L/min TB:0.1°C TI:0.1°C
Anesthesia Gas Analysis(0ption)
Method: Infrared Absorption
Gas Sorts: CO2,N2O, Des, lso, Enf, Sev,
Hal and optional O2
Measurement range: CO2:0~13.6%;N2O:0~100%;
O2:0~100%;Hal: 0~8.5%,
Iso:0~8.5%;Enf: 0~10%;
Sev:0~10%;Des:0~20%
RR(Respiration rate): 0~100rpm
Data input: Fi and Et values
Agent mixture detection
Configuration
Standard configuration
ECG, NIBP, SPO2, RESP,2TEMP, HR/PR, Rechargeable battery
Optional configuration
Built-in Thermal Printer, 12-ead ECG, Nellcor SPO2, Masimo SPO2,2-IBP, 4-IBP, Suntech NlBP, ETCO2, CO, Anesthesia Gas Analysis,Touch Screen, Wireless Network,12-Volt Power Supply, High Capacity Battery, Carry Bag, Wall Mount, Moving Cart