YSTE240 Automatic Chemistry Analyzer |
|
Specifications |
Analyze System |
Throughput |
Maximun 240T/h |
Theory |
Absorption spectronmetry,Transmission turbidimetry |
Methodology |
End-point,Fixed-time,Kinetic,Monochromatic/bichromatic |
Test according set up,random access |
Reaction plate |
Contain 81 reaction cuvettes |
Maximun reaction time |
15 minutes |
Minimum reaction volume |
150 ul |
Material of cuvettes |
Special UV-transparent optical glass |
One-off cuvettes,can update to automatically cuvettes washing |
Optical System |
Light Source |
Halogen-tungsten lamp |
Photometer |
Reversed optics |
Wavelength |
340nm-900nm wavelength option |
Absorption |
0-4 Abs |
Reagent/Sample Handling |
Sample volume |
2-100 ul,step by 0.1 ul |
Sample plate |
Contain60 sample positions |
Reagent/Sample Probe |
Automatically checked,patent technology liquid level detection,collision protection Probe cleaning:Automatic washing for both inside and outside |
Samples cup |
Support one-off blood cuvettes、micro cups、plastic cuvettes |
Reagent volume |
20-500 ul,step by 1 ul |
Reagent plate |
Contain 20 reagent positions |
Sample/reagent probe |
Collision protection liquid level detection;Internal and external probe washing;Probe depth adjustment automatically |
Reagent bottle |
15ml & 30ml; Dead volume less than 0.5 ml |
Temperature Control |
Maintenace free heater elements |
Temperature maintainance within 3 minutes |
Temperature of reagent compartment |
4-12℃ |
Reaction temperature |
37±0.1℃ |
Temperature fluctuation |
±0.1℃ |
Operation System |
Software |
WindowsXP、2000 |
Database |
SQL Server |
Data Storage |
Automatic store & copy;No time and volumn limit;Lifetime preservation |
Print format |
Can be set up,offer several standard format |
Calibration mode |
Linear curce type:Single-point linear,two-point linear and multi-point linear none linear;Curve type:Logistic-Log 4P,Logistic-Log5p,Spline,index automatically use best calibration curve and standard |
QC Methods |
Real time,within day & between day |
Quality Control Diagram |
L-J、cumulative、twin plot |
Control software |
Random set up,default westgard multi-rule |
Status display |
Real time monitoring of reagent residual volume Running status of reagent tray,samples tray |
Adjustment |
Dynamic and real time display of running status;Intelligent carry over settings to adjust test sequence;Original reaction data record;Detail profile of alert messages |
Setting |
Operation permission setting,Item setting,cross polution setting,cuvette blank setting |
Others |
Water consumption |
Less than 1 L per hour |
Power Supply |
AC 220V±22V 50Hz±1Hz |
Frequency |
Maximun 200VA |
Dimension |
720mm×581mm×545mm |
Weight |
60kg |
Accessory |
Software |