Smart Veterinary BP Vital Signs Monitor YSPM-PET5: 5.5″ capacitive touchscreen for large & small animals with SPO₂, NIBP, ECG, temp, wireless data transfer and 6 h battery.
Transportation and Storage Temperature:-20~50°C Humidity:10%~90%(non-condensing) Atmosphere pressure:86KPa~106KPa
Trend & Reviewing NIBP measurementreviewing:1500groups Waveform review: 3 hours 600groups Alarm event: 1000 groups of parameter alarmsevents and associated parameter
Respiration Method: Impedance between RA-LL Gain:x0.25,x0.50,x1,x2,x4 Respiration Rate:0~120/0-150BrPM Sweep speed: 6.25 mm/s, 12.5 mm/s,25mm/s Resolution:1 BrPM Apnea Alarm:10~40s Measure range: Large animal: 0-120 bpm Small animal: 0-150 bpm
Temperature Technique: Thermistor probe (2.25K/10k) Measuring and Alarm Range:0.0°C~50°C Unit: Celsius (°C) Resolution:0.1°C or 1F Accuracy:±0.1°C(exclusive probe)
ECG Lead mode: 3/5 Leads, l, ll, lll or l, l, lll, AVR, AVL, AVF,V Gain: 1/4 file (X0.25)2.5mm/mV; 1/2 file(X0.50)5.0mm/mV; 1 file (X1)10mm/mV; 2 files (X2)20mm/mV; Sweep speed: 6.25mm/s, 12.5mm/s,25mm/s; Baseline Recovery: <3s after defibrillation (Monitor mode) <1s after defibrillation (Surgery mode) Bandwidth: Diagnostic 0.05~100 Monitor 0.5~40Hz Surgery 1~20Hz
Heart Rate Measure range
large animal
15~300 bpm
small animal
15~350 bpm
accuracy
1% or 1bpm, whichever is greater
resolution
1 bpm
SpO2 Measurement Range:0~100% Resolution:1% Response Modes:Low, Medium, High Accuracy: 70%~100%:2% <69%:unspecified Support Pitch tone and multi-level volume Pulse Rate Measuring and Alarm Range: 25~250bpm Accuracy:± 3bpm Resolution:1bpm
NIBP Method:Pulse wave oscillation method Measure mode:Manual, Auto, Continue Measure interval in auto mode: 1,2,3,4,5,10,15,30,60,90,120,180,240,480min STAT mode cycle time:Keep 5 minutes Measure and Alarm Range: Large Animal
SYS
30~280mmHg
DIA
10~220mmHg
MEAN
20~240mmHg
Small Animal
SYS
30-220mmHg
DIA
10~160mmHg
MEAN
20~170mmHg
Static pressure range
0~300mmHg
Static pressure accuracy
3mmHg
Accuracy: Maximum Mean error 5mmHg; Maximum Standard deviation 8mmHg Static pressure accuracy: ± 3mmHg Resolution:1mmHg Accuracy:Maximum Mean error ± 5mmHg; Maximum Standard deviation<8mmHg Over pressure Protection:large animal-300mmHg; small animal-240mmHg
EtCo2(Mainstream/Sidestream)(Optional) Measure method:Non-dispersive infrared (NDIR) Measure Range: 0~19.7%(0~150mmHg) 0-20kPa Resolution:0.1 mmHg CO2 Accuracy: 0-40 mmHg, ±2 mmHg 41~70 mmHg, ±5% of reading 71~100 mmHg, ±8% ofreading 101~150 mmHg,±10% ofreading at 760mmHg, ambient temperature of 25°C Respiratory Rate: Range:3~150BrPM Accuracy:±1bpm