·Classic
Vet MRI combined many pioneering MRI imaging technology and human-based humanized design concept, making it achieve high. Vet MRI led a technical revolution in the permanent MRI field. It provides clear images and stable system quality, the system is used for rabbits, cats, monkeys, dogs, it can make an accurate diagnosis of pet animal diseases with a reliable basis, in order to facilitate the veterinarian hospitals in the diagnosis and treatment. The system is applicable to the laboratory, pet hospital, etc.
Vet MRI system, not only had accumulated the products’ technical essence from major companies home and abroad, but also followed the developing trend, and with constant innovation, a breakthrough in the industry field and achieved:
· Eddy Zero Technology
Make sure the imaging quality achieved qualitative improvement.
The shimming algorithm technology (ensure field strength with high uniformity and stability), ensure the MRI system operates stably with high quality and high performance.
The high magnetic uniformity, high stability, fast and accurate position operation are always the hard breakthrough technical bottleneck. Vet MRI system not only breakthrough the bottleneck historically, and achieved the “high stability, high performance, high imaging quality and high efficiency”. And with the specially designed high power gradient magnet field for Vet MRI, it achieved as an all-new concept Vet MRI system.
·Much Open, Easy for The Operator
More space for surgery. Affinity C-shape magnets, creating a maximum of openness, offer a maximum vision for doctors, especially leaving much space for operation.
·High-performance Gradient System
Gradient system helps to provide higher resolution pictures, Vet MRI’s gradient system(X、Y、Z) gradient intensity is 15mT/m, Higher the gradient intensity, faster imaging speed, shorter of scanning time; Higher the gradient intensity, thinner of imaging slice, higher of image resolution.
· The New Technology
4D shimming:
Use of advanced active shimming algorithm for real-time automatic shimming on each examination to ensure the magnetic field always maintains the highest uniformity. Magnetic field homogeneity and stability of the MRI images always are the most important guarantee of the high-resolution, high SNR and high contrast.
They are the important indicators of the level of magnet design, the better the smaller the value, directly determines the SNR of the image, like a car chassis, stability is essential.
Eddy Zero Technology:
a)Magnet design uses breakthrough anti-eddy current technology
b)The gradient coil using self-shielded active anti-eddy current technology
c)Implementation of precision eddy current compensation algorithm, completely eliminate the impact of eddy current
The eddy current together with the high gradient and high slew rate coming from the ultra-fast sequence was resolved completely, guaranteeing to get the best clinic image.
· Advanced RF System
Fast 2 channels RF system. All phased array coils provide the best SNR pictures.
Specification
No.
Item
Specification
1
Magnet System
1.1
Magnet Type
Permanent magnet with automatic constant temperature system
1.2
Field strength
0.5T / 0.35T
1.3
Magnet shape
Open type
1.4
Homogeneity(40cm, DSV, Vrms)
≤2.5ppm
1.5
Shim method
Active/Passive/Dynamic
1.6
Magnet vertical gap
40cm / 35cm
1.7
Accessibility(Horizontal opening angle)
>250°
1.8
5 Gauss fringe field
2.5m*2.5m*2.5m
2
Gradient System
2.1
Gradient field strength(Single Axis)
≥18mT/m
2.2
Gradient slew rate (Single Axis)
≥45mT/m/ms
2.3
Rise time
<0.3ms
2.4
Gradient cooling system(Gradient coils and power electronics)
Air
3
RF System
3.1
Spectrometer
Fully digital
3.2
RF system type
Digital Transmit and Receive
3.3
Number of RF channel
4
3.4
Transmitter amplifier peak power
5kW
3.5
RF bandwidth of the receiver
Each >400KHz
3.6
Dynamic range
≥80dB
3.7
Noise factor
0.3dB
3.8
Coil type
Phased array
4
Scan environment
4.1
Max. vetweight
135kg / 200Kg
4.2
High accurate position assist
Yes
4.3
Localizer
Yes
4.4
Position accurate
≤1mm
4.5
Position accessories
Yes
4.6
Emergency stop
Yes
4.7
Communication system
Yes
5
Computer system
5.1
Host computer
Dual-core
5.2
System software
5.3
OS
WINDOWS
5.4
CPU clock rate
≥2.8GHz, be able for extension
5.5
Main memory
≥2GB, be able for extension
5.6
Color LCD monitor
24”
5.7
Keyboard and mouse
Standard
5.8
Hard disk
≥500GB, be able for extension
5.9
Media driver
CRW / DVD
5.10
DICOM 3.0
Yes
5.11
Ethernet
Yes
6
Scanning parameter
6.1
Max. FOV (recommend)
300mm
6.2
Min. FOV (recommend)
90mm
6.3
Max. Image matrix
512*512
7
Scanning sequence &imaging technology
7.1
Spin echo 2D/3D (SE 2D/3D)
Yes
7.2
Multi-slice multi-echo(MSME)
Yes
7.3
Gradient echo(GRE 2D/3D)
Yes
7.4
Steady-state process gradient echo( SSPGRE)
Yes
7.5
Fast spin-echo (FSE)
Yes
7.6
Fast double echo(FDE)
Yes
7.7
Fast recover fast spin-echo(FRFSE)
Yes
7.8
Single-shot fast spin-echo(SSFSE)
Yes
7.9
Multi-shot fast spin-echo (MSFSE)
Yes
7.10
Inversion recovery (IR)
Yes
7.11
Inversion recovery fast spin-echo (IRFSE)
Yes
7.12
Short time inversion recovery (STIR)
Yes
7.13
Fluid attenuated inversion recovery (FLAIR)
Yes
7.14
Gating technology
Yes
7.15
Section scan
Yes
7.16
TOF 2D MRA
Yes
7.17
TOF 3D MRA
Yes
7.18
Diffusion-weighted imaging (DWI)
Yes
7.19
Max. b Value
1000s/mm2
7.20
Magnetization transfer (MTC) technology
Yes
7.21
MIP
Yes
7.22
Invert film
Yes
7.23
3D position
Yes
7.24
Pre-saturation technology (PS)
Yes
7.25
Pre-saturation adjustment technology
Yes
7.26
Part metal implant scan technology
Yes
7.27
Automatic coil tuning
Yes
7.28
Head scan package(Vet)
Yes
7.29
Body scan package(Vet)
Yes
7.30
Bone scan package (Vet)
Yes
7.31
Online image filtration
Yes
7.32
Online post procession
Yes
7.33
Optimal algorithm of active shimming
Yes
7.34
Scan sequence queuing
Yes
7.35
Multi-layer and multi-angle scanning technology
Yes
7.36
Optimize bandwidth acquisition technology
Yes
7.37
Flow compensation
Yes
7.38
Parallel acquisition technology
Yes
7.39
Section acquisition technology
Yes
7.40
Scan parameter preset
Yes
7.41
Oversampling technology
Yes
7.42
Image fusion technology
Yes
7.43
Artifact suppression technology
Yes
7.44
Thin imaging technology
Yes
7.45
Movie playback technology
Yes
7.46
Post-processing package
Yes
Configuration
Standard Configurations
Unit
Quantity
Standard Hardware includes:
RF shielding room
set
1
Permanent Nd-Fe-B magnet, Full open C-shaped eddy current-free self-consistent temperature magnet 0.35T
set
1
Spectrometer
pc
1
Preamplifier
set
1
RF amplifier
pc
1
Flat-panel transmitter coil
set
1
Gradient amplifier
pc
1
Gradient coil
set
1
Computer
set
1
Imaging monitor
set
1
Diagnostic table
set
1
Large Vet coil
set
1
Middle Vet coil
set
1
Small Vet coil
set
1
Tablepats
set
1
Quality control water phantom
pc
1
MRI safety marks
set
1
Technical manual
pc
1
User manual
pc
1
Maintenance manual
pc
1
3-phase AC voltage stabilizer
pc
1
Magnet self-consistent temperature system
set
1
Dual-voice-communication system
set
1
Laser location system
set
1
Standard Software include
Imaging software
set
1
Pulse sequence
set
1
Imaging enhancement software
set
1
DICOM interface software
set
1
Vet vascular imaging software
set
1
Diffusion imaging package
set
1
MR CINE
set
1
Imageanalyzingsoftware
set
1
Quality control software
set
1
Remark: RF shielding rooms are including RF shielding room decoration, RF shielding door, observation window, transmission board, Waveguide plate, interior lighting; excluding room construction and flooring, outside decoration of RF shielding room, operation room, equipment room, air-conditioned room and air-conditioner, external electric access and the independent ground lead.
Provide the technical staff for installation, including RF shielding room installation, MRI system installation, and training;
The buyer shall bear round trip air ticket from China to the installation country, local transportation, food and board of 's technicians in the country of installation for the purpose of installation, training and service.
Contents are subject to change without prior notice
Get Price
Write down your demand below and we will contact you within 24h!