We use cookies to improve your online experience. By continuing browsing this website, we assume you agree our use of cookies.
icon email
icon map
Haizhu District,
Guangzhou, 510000
icon phone
TEL: +86-20-34174605
MOB: +86 17727659022(whatsapp)
Categories

YSF6II Multi-parameter Patient Monitor 7"

Item No.: YSF6II
Parameter :  5 Lead ECG, RESP, Digital SpO2, NIBP, TEMP.
Standard Configuration:
SpO2, NIBP, PR, TEMP, RESP, ECG
Optional Configuration:
2-TEMP, Printer(50mm), Trolley/Wall mount, Nellcor SpO2, Central Monitor System
  • BrandYSENMED
  • Model numberYSF6II
  • Warranty1 Year
  • CustomizedOEM
  • Lead time7 Working Days
  • PackageStandard Package
  • Description
    Features
    7’’ TFT  LCD display, high resolution. 
    Built-in rechargeable battery. 
    User-Friendly operational window. 
    60s full disclosure of ECG playback. 
    48 hours tabular and graphic trends & data storage. 
    Digital SpO2, high capacity against interference of ESU, motion & low infusion. 
    Isolated against defibrillation effect. 
    Wireless or wire communicable with central station system. 
    Parameter :  5 Lead ECG, RESP, Digital SpO2, NIBP, TEMP. 
    Standard Configuration:
    SpO2, NIBP, PR, TEMP, RESP, ECG
    Optional Configuration:
    2-TEMP, Printer(50mm), Trolley/Wall mount, Nellcor SpO2, Central Monitor System


     










    NIBP
    Method: Oscillometry
    Measure mode: Manual, Auto, STAT
    Measure interval in auto mode:
    1~5/10/15/30/60/90/120/180/240/480min
    Measure period in STAT mode: 5min
    Pulse rate range: 40 ~ 240bpm
    Measure & alarm range: Adult
    SYS 40 ~ 280mmHg
    DIA 10 ~ 220mmHg
    MEAN 20 ~ 240mmHg
    Pediatric
    SYS 40 ~ 220mmHg
    DIA 10 ~ 160mmHg
    MEAN 20 ~ 170mmHg
    Neonatal
    SYS 40 ~ 135mmHg
    DIA 10 ~ 100mmHg
    MEAN 20 ~ 110mmHg
    Static pressure measurement
    Range: 0 ~ 300mmHg
    Accuracy: ± 3mmHg
    Resolution: 1mmHg Accuracy:
    Max. Mean Error: ± 5mmHg
    Max. Standard Deviation: 8mmHg
    Overpressure protection:
    Adult 300mmHg
    Pediatric 240mmHg
    Neonatal 150mmHg
    SPO2
    Measurement range: 0 ~ 100%
    Resolution: 1%
    Accuracy: 70% ~ 100% ± 2%
    40% ~ 69% ± 3%
    Environment
    Operating environment :
    Temperature: 0 ~ 40 ℃
    Humidity: 15% ~ 80%
    Pressure: 86.0 kPa ~ 106.0kPa
    Transport and Storage environment :
    Temperature: -20 ~ 55 ℃
    Humidity: 10% ~ 90%
    Pressure: 86.0 kPa ~ 106.0kPa
    YSPM80C MULTI-PARAMETER PATIENT MONITOR
    Model NO.: YK-8000C
    Quality Standards and Classification
    CE, ISO13485
    SFDA: Class Ⅱb
    Anti-electroshock degree:
    ClassⅠequipment
    (internal power supply)
    TEMP/SpO 2 /NIBP: BF
    ECG/Resp: CF




     
     
    Get Price
    Write down your demand below and we will contact you within 24h!

    Review

    1/3
    X