| Physical Specifications | |||||
| Dimension and Weight | Dimension | 32cm (W)*26cm (D)*8cm (H) | |||
| Weight | standard configuration: 2.8 kg | ||||
| Operation Environment | Power requirements | AC100-240V , 50/60Hz | |||
| Power | 50VA | ||||
| Temperature | 0-40℃ | ||||
| Humidity | 0-93% non-condensing | ||||
| Fetal/Maternal Performance Specifications | |||||
| Performance Specifications | Display | 10.4 inches (1024×768 pixel) color TFT –LCD | |||
| Indicator | Visual on-display and integrated, alarm light, audible alarm | ||||
| Battery | Internal rechargeable Li-ion battery power | ||||
| Alarm | Visual on-display and integrated, alarm light, audible alarm | ||||
| Memory | 24-hours memory for fetal traces 150 groups patient data |
||||
| Printer | America standard/international standard Built-in thermal printer (paper width:110mm) 1/2/3cm/min real-time printing speed, fast print speed (stored traces) |
||||
| Paper | Z-fold, thermosensitive | ||||
| Record Message | ID, name, age, date, time, print speed etc | ||||
| CMS | Support connecting to central monitoring station through LAN (TCP/IP) or wireless connection | ||||
| Fetal/Maternal Technical Specifications | |||||
| Ultrasound (FHR) | Measurement range | US | 30 to 240 bpm | ||
| Resolution | Display | 1bpm | |||
| Printer | 1bpm | ||||
| jitter@200 bpm | ≤3bpm | ||||
| Display update rate | 0.25second | ||||
| Beat to bea change(max.) for ultrasound | 28bpm | ||||
| US frequency | 1MHz±5%Hz | ||||
| TOCO | Measurement method | Strain gauge sensor element | |||
| Sensitivity | 1 unit =2.5g | ||||
| Resolution | 1 unit | ||||
| Measurement range | 500 units | ||||
| Baseline setting | 0, 5,10, 15, 20 can be selective | ||||
| Update rate | 0.25 second | ||||
| Auto offset correction | 3 second after connecting the transducer | ||||
| Auto zero adjust | TOCO value is set to zero negative following a negative Measure value for 5 seconds |
||||
| Auto Fetal Movement (AFM) | Technique | Pulsed doppler ultrasound | |||
| Range | 0-100% | ||||
| Resolution | 1% | ||||
| Automatic fetal movement actograph | |||||
| Manual fetal movement marker | |||||
| Maternal NIBP(MNIBP) | Operation mode | Manual/automatic/ STAT | |||
| Measurement unit | mmHg / kPa selectable | ||||
| Test interval | 0-480 minutes | ||||
| Accuracy | Max.Std.deviation:8 mmHg(1.1kPa) | ||||
| Max. mean Error: ±5mmHg(±0.7kPa) | |||||
| Measurement range | Systolic | 30 to 270 mmHg(4 to 36 kPa) | |||
| Diastolic | 10 to 245 mmHg(1.5 to 32kPa) | ||||
| Mean | 20 to 255 mmHg(2.5 to 34kPa) | ||||
| Pulse rate range | 20-250bpm | ||||
| Over-pressure protection | Yes | ||||
| Maternal SpO2 (MSpO2) | Measurement range | 0%-100% | |||
| Resolution | 1% | ||||
| Accuracy | ±2% | ||||
| Pulse rate range accuracy | ±3bpm | ||||