YSZS-BD320 needle cutter and destroyer

Item No.: YSZS-BD320
Feature:
l  It can work under AC power source only;
l  Low voltage electric shock can melt the needle instantly; mechanic cutting can melt syringe body, double overheating protection is provided;
l  There will be little electrical spark which is normal
  • BrandYsenmedical
  • Model numberYSZS-BD320
  • Warranty1 year
  • Customizedyes
  • Lead time7 days
  • Packagecarton
  • Description
    YSZS-BD320 needle cutter and destroyer
    Feature:
    l  It can work under AC power source only;
    l  Low voltage electric shock can melt the needle instantly; mechanic cutting can melt syringe body, double overheating protection is provided;
    l  There will be little electrical spark which is normal during melting;
    l  Indicator light sparks during melting, showing the needle is under destroying, the whole process cost only 1 to 3 seconds.
    l  Destroy Needle specifications 30G---34G
     
    Specification:
    l  Power: AC 110V±10%/220V±10%;
    l  Melting method: melt with low pressure, high temperature;
    l  Working time: can destroy around 240 continuously (take 20ml syringe body as reference)
    l  Working noise:50 dB
    l  Electrode chip working voltage: AC 8V
    l  Power: <130VA
    l  Electrode chip overheating protection temperature: 85
     
    Package:
    l  Single unit      Dimension: 25cm x 22cm x 18cm      Gross weight: 2kg
    l  18 pcs/carton    Dimension: 54cm x 44cm x 42cm      Gross weight: 27kg





    Technical Specification:

    Infusion rate range
    Adjustable drop rate range: 1 /min~400 drops/min 
                              (step: 1 drop /min)
    Adjustable flow rate range: 1ml/h~1200ml/h
                             (step 0.1ml/h)
    Purge rate: 800ml/h
    KVO rate: 1ml/h (less than 100ml/h)
              2ml/h (100~300ml/h)
              3ml/h (greater than 300ml/h)
    Infusion volume range: 1ml~9999.9ml (step: 0.1 ml)
    Maximum accumulated volume: 9999.9ml (step: 0.1 ml)
    Infusion Time range: 1min~9999min (step: 1 min)

    Infusion accuracy: Within ±3% (using calibrated high quality IV set)
                       Mechanical precision: within ±2%

    Occlusion alarm threshold:
             High: 800 mmHg ± 200 mmHg (106.7kPa±26.7kPa)
    Medium: 500 mmHg ± 100 mmHg (66.7kPa±13.3kPa)
    Low: 300 mmHg ± 100 mmHg (40.7kPa±13.3kPa)
    Alarm: Infusion Complete, Empty, Faulty Signal, Misoperation, Occlusion, Door Open, Air Bubble, Low Battery, Setting Error, AC power off, Idle.

    Size: 515mm(L)×145mm(W), allowed deviation: ±5%

    SpO2 sensor
    Type: Finger clip type
    Wire length: 3000mm, allowed deviation: ±5%
    Human body contact materials: Silicone

    Size: 188 mm(L)×198 mm(W)×228 mm(H)
    Net weight: 2.5kg

    Technical Specification:

    Infusion rate range
    Adjustable drop rate range: 1 /min~400 drops/min 
                              (step: 1 drop /min)
    Adjustable flow rate range: 1ml/h~1200ml/h
                             (step 0.1ml/h)
    Purge rate: 800ml/h
    KVO rate: 1ml/h (less than 100ml/h)
              2ml/h (100~300ml/h)
              3ml/h (greater than 300ml/h)
    Infusion volume range: 1ml~9999.9ml (step: 0.1 ml)
    Maximum accumulated volume: 9999.9ml (step: 0.1 ml)
    Infusion Time range: 1min~9999min (step: 1 min)

    Infusion accuracy: Within ±3% (using calibrated high quality IV set)
                       Mechanical precision: within ±2%

    Occlusion alarm threshold:
             High: 800 mmHg ± 200 mmHg (106.7kPa±26.7kPa)
    Medium: 500 mmHg ± 100 mmHg (66.7kPa±13.3kPa)
    Low: 300 mmHg ± 100 mmHg (40.7kPa±13.3kPa)
    Alarm: Infusion Complete, Empty, Faulty Signal, Misoperation, Occlusion, Door Open, Air Bubble, Low Battery, Setting Error, AC power off, Idle.

    Size: 515mm(L)×145mm(W), allowed deviation: ±5%

    SpO2 sensor
    Type: Finger clip type
    Wire length: 3000mm, allowed deviation: ±5%
    Human body contact materials: Silicone

    Size: 188 mm(L)×198 mm(W)×228 mm(H)
    Net weight: 2.5kg





    Get Price